82.5 – 125 KVA

Prime Rating at rated rpm ( as per ISO8528)1

kVA

82.5

100

125

125HD

kW

66

80

100

100

Genset Model

KG1- 82.5WS

KG1- 100WS

KG1- 125WS

KG1-125WS HD

Frequency

Hz

50

50

50

50

Power factor

lagging

0.8

0.8

0.8

0.8

Voltage

V

415 3Ø

415 3Ø

415 3Ø

415 3Ø

Governing class (As per ISO 8528 Part-V)

G2

G3

G3

G3

Noise level

dBA

< 75

< 75

< 75

< 75

Fuel Consumption*

At 100 % Load

Ltrs/hr

18.8

21.9

27.4

29.6

At 75 % Load

13.8

16.9

20.2

22.4

At 50 % Load

9.9

12.2

15.3

15.3

Fuel tank capacity

Ltrs

150

230

230

230

Overall dimensions of genset (L x W x H)^

mm

3200 x
1100 x
1595

3200 x
1300 x
1795

3200 x
1300 x
1795

3650 x
1350 x
1915

Dry weight of genset with canopy (approx..)^

Kg

1710

2040

2090

2450

Wet weight of genset with canopy (approx..)^

Kg

1840

2240

2290

2650

Electrical Battery starting voltage

Volts-DC

12

12

12

12

ENGINE

Engine Model

 

4R1040TA G1

4K1080TA G2

4K1080TA G2

6R1080TA G1

Rated output (Prime Continuous rating as per
)

kW

74.8

114.7

114.7

114.7

HP

102

156

156

156

No. of cylinder

Number

4

4

4

6

Cubic capacity 2

Ltrs

4.16

4.32

4.32

6.49

Bore x Stroke

mm

105 x 120

105 x 125

105 x 125

105 x 125

Rated Speed

RPM

1500

1500

1500

1500

Aspiration

NA/TC/TA

TA

TA

TA

TA

Lube Oil change period

hrs.

500

500

500

500

Lube oil Sump Capacity

Ltrs

10

18

18

12

Coolant Capacity

Ltrs

24

21

21

28

ALTERNATOR

Insulation Class

Class H

Alternator Efficiency (at 100% load) 0.8 pf**

%

91.4

92.0

92.5

92.5

Max Voltage Dip at Full Load 0.8 pf Lag

< 20 %

< 20 %

< 20 %

< 20 %

Max Time to build up rated voltage at Rated RPM

sec

< 5 sec provided engine reach the rated speed

For intermediate ratings, kindly contact nearest KOEL office

Notes
^ Tolerances Apply
*With 0.845 Specific Gravity of diesel ( 5 % Tolerance )

** Efficiency of Alternator as per standards IS 4722 and IEC 34-1 For Site Conditions other than standard operating conditions consult KOEL for available prime power.
  • kirloskar genset dealers in Chennai

Prime rating and Stand‐by rating1

‘Prime power’ is designed for Unlimited hours, as compared to ‘Emergency stand-by’ designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. KOEL offers Prime power as standard offer. Contact KOEL for stand-by ratings.

Engine capacity does matter2

Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.

Higher engine capacity also enables Genset to respond quickly & positively to sudden load additions.

3. Engine

O2E Series: Low emission, high efficiency engines
Compact, Robust and Rugged Design
500 hours lube-oil change period

1. Canopy

Ease of Access and Serviceability
Aesthetically designed, weather and sound resistant enclosure
Insulation conforms to UL94-HF1 class for flammability

2. Controller

Microprocessor based fully configured
Graphical bigger LCD display
Best in class monitoring and diagnostic
Integrable with AMF, synchronization & communication configurations

4. Alternator

Best In Class Efficiency
Special Windings to Reduce Harmonics
Vacuum Pressure Impregnation and epoxy gel coating on winding

Koel’s approach to meet revised CPCB norms1

Revised CPCB norms are aimed at protecting the environment by reducing Genset emissions and improving enission quality.These are some of the most stringent emission norms in the world

To meet the new norms, KOEL R & D team had choice of multiple technologies. While selecting the technology, KOEL laid significant emphasis on long term needs of users viz:

High reliability and durability of Gensets: Owing to extreme opera & ng conditions in India, preference has been given to robust configurations that have been running successfully for several years
Low running costs: An effort to reduce emissions tends to increase the running costs. KOEL has succeeded in achieving both in the same design.
Optimized fuel efficiency as per actual usage: KOEL Green Gensets are tuned to provide maximum fuel efficiency in the most common operating band. At KOEL, we call it O2E series (Optimal Operating Efficiency).
Affordable, On‐site support: Proven technology ensures that product support is available close‐by, without waiting for a specialist. KOEL team has taken special efforts to keep complex technologies at bay, which may require high on‐site maintenance costs
All this, while keeping the initial costs within the reach of a smart Genset buyer